Test and tag requirements in SA, Tasmania, the ACT and the NT
Test and tag requirements in Australia's smaller jurisdictions: what SA, Tasmania, the ACT and the NT require, who can test, intervals, RCDs and records.

Test and tag requirements across Australia are similar in principle but differ in the detail. South Australia, Tasmania and the ACT use the model Work Health and Safety (WHS) laws, and the Northern Territory moved its test and tag rules into its Electrical Safety Regulations 2024. In all four, plug-in equipment used in harsh conditions must be regularly inspected and tested by a competent person. The differences are in who counts as competent, how specific the regulator is about intervals, and how each jurisdiction treats RCDs and construction sites.
This page covers those four. For the larger states, see our guides to Queensland, NSW, Victoria and WA.
General information only, not legal advice. Rules and fees change, and this page reflects regulator pages we read on 7 November 2026. Check the current regulator guidance for your jurisdiction and the relevant standards before you quote or test: SafeWork SA, WorkSafe Tasmania, WorkSafe ACT and NT WorkSafe.
The short version
| South Australia | Tasmania | ACT | Northern Territory | |
|---|---|---|---|---|
| Test and tag law | WHS laws, with a published interval table | WHS laws | WHS Regulation 2011 | Electrical Safety Regulations 2024, regs 67 to 71 (from 1 July 2024) |
| Who can test | A competent person: a nationally accredited portable appliance course, or a licensed electrical worker | Not a licensed occupation: electricians, or interstate people with the required training | A licensed electrician or a person certified as competent | A competent person: an electrician, or someone trained in pass-fail portable appliance testing |
| Intervals | Table on SafeWork SA's site | Left to the code of practice and risk | Follow AS/NZS 3760:2022 and AS/NZS 3012:2010 | At least every 12 months as a general rule in higher risk environments, with shorter examples |
| Records | Name, date, outcome, next test date | Not itemised on the pages we found | Compliant equipment gets a durable, non-reusable, non-metallic tag | Name, date, outcome, next test date |
South Australia
SafeWork SA says a business must make sure electrical equipment is regularly inspected and tested by a competent person if it is supplied through a socket outlet and used where normal use is likely to damage it or shorten its life, such as moisture, heat, vibration, mechanical damage, corrosive chemicals or dust. Its page lists expiation fees for breaches, for example $432 for an individual and $2,160 for a body corporate for the testing duty itself.
Who can test in SA
SafeWork SA says only a competent person can inspect and test. That can be someone who completed a nationally accredited course from a registered training organisation on portable appliance testing, or a licensed electrical worker deemed competent for the task. The nationally recognised unit is UEERL0003, and clients often ask to see your statement of attainment.
SA test intervals
SA is the most specific of the four. SafeWork SA's page publishes a full interval table based on AS/NZS 3760:2022, covering equipment and RCDs by environment, plus a separate construction table tied to AS/NZS 3012. For example, it lists 6 months for factories and workshops, 12 months where equipment is flexed in normal use or in a hostile environment, and testing every 3 months for hire equipment, which must also be inspected before each hire. Read the full table on the page before you set a client's schedule. Our frequency guide explains how the standard's intervals work, and our RCD testing guide explains push-button and operating-time tests.
SA records and new equipment
A record must show the tester's name, the test date, the outcome and the date the next test can be done. It can be a tag, logbook, register or database, and must be kept until the next test or until the equipment is permanently removed or disposed of. On construction and demolition sites, SafeWork SA also expects a register of all equipment, a repair register and records of faulty equipment, with RCD test results kept for a minimum of five years. Newly purchased equipment is treated as tested by the manufacturer but must be inspected for obvious damage, and new equipment used for construction work must be tagged with its next due date.
Tasmania
WorkSafe Tasmania's electrical hazards page says businesses must manage electrical risks and that periodic testing and tagging must be done. It points to the national code of practice, Managing electrical risks in the workplace, for the detail. We couldn't find a Tasmanian page that sets out intervals or record contents the way SafeWork SA and NT WorkSafe do, so for those, work from the code of practice, AS/NZS 3760 and the client's risk assessment, and ask WorkSafe Tasmania if you're unsure.
Who can test in Tasmania
Tasmania's Consumer Affairs licensing page states that testing and tagging electrical appliances is not a licensed occupation in Tasmania. Licensed electricians are automatically qualified, and interstate people who have completed the required training can test and tag there. That page was last updated in 2019, so check it hasn't changed. Repairs are different: you need an electrical practitioner licence for electrical work.
Tasmanian construction sites
WorkSafe Tasmania's RCDs on construction sites page says installations must comply with AS/NZS 3000 and AS/NZS 3012. It gives these RCD checks:
- Portable RCD socket assemblies: push-button test after connecting and before connecting equipment, or at least once a day, and an operating-time test every 3 months.
- Fixed RCDs: push-button test every month and an operating-time test every 12 months.
- Records: test records must be kept and available for review. Portable equipment gets a durable, non-reusable, non-metallic tag stating who tested it and the test or retest date.
See also our guide to test and tag on construction sites.
The ACT
WorkSafe ACT says the Work Health and Safety Regulation 2011 prescribes mandatory testing and tagging for electrical equipment used where operating conditions are likely to damage it or shorten its life, such as moisture, heat, vibration, mechanical damage, corrosive chemicals or dust. It says inspections are to be carried out by a licensed electrician or a person certified as competent to do the testing.
The ACT page ties testing to three standards: AS/NZS 3760:2022, AS/NZS 3012:2010 for construction and demolition sites, and AS/NZS 3002:2008 for shows and carnivals. It lists the checks that in-service testing should include, where applicable: an external inspection, earth continuity for Class I equipment, power boards and cord sets, insulation resistance or leakage current, and polarity on cord sets with re-wireable plugs and extension sockets.
Two ACT points to note:
- Tagging and unsafe equipment. Compliant equipment is fitted with a durable, non-reusable, non-metallic tag or other indicator. Unsafe or untested equipment must be disconnected and not reconnected until it's repaired, tested and found safe, or replaced or removed.
- Electric shocks are notifiable. A WorkSafe ACT safety alert says an electric shock must be reported to WorkSafe ACT even if no one was injured. Mention this to clients after a failed item that has already given someone a shock.
We didn't find a WorkSafe ACT page that sets fixed intervals, so base intervals on AS/NZS 3760:2022 and our frequency guide.
The Northern Territory
The NT is the one to watch, because older guides are out of date. From 1 July 2024, NT WorkSafe says, the testing and tagging rules moved from the Work Health and Safety (National Uniform Legislation) Regulations 2011 to regulations 67 to 71 of the Electrical Safety Regulations 2024. Some NT WorkSafe bulletins still refer to the older regulations, so cite the new ones.
What the NT WorkSafe bulletin says:
- Hostile environments. A business must do all that is reasonably practicable to make sure socket-supplied equipment used in a hostile environment is regularly inspected and tested by a competent person, and not used if it should have been tested and hasn't been.
- Lower risk environments. There is no mandated inspection, testing or tagging for equipment in dry, clean, well-organised places like offices, retail shops and classrooms, though a business can include them in its risk management.
- Intervals. As a general rule, test at least every 12 months in higher risk environments, with examples of every 6 months for manufacturing, workshops and commercial cleaning equipment, and every 3 months for hire equipment and construction and demolition sites. Hire businesses must inspect at the start of each hire and test every 3 months.
- Extra low voltage. Power supplies below 50 volts AC or 120 volts DC that plug directly into a socket, and extra low voltage items, don't need testing or tagging.
- RCDs. Regulation 69 requires all safety switches in a workplace to be tested to AS/NZS 3760 straight after connection and at the standard's intervals. Faulty safety switches must be tagged out until repaired or replaced.
- Records. A record must show who tested, the date, the outcome and the next test date, and be kept until the next test, permanent removal or disposal. A tag, logbook, register or database can be the record.
On who can test, NT WorkSafe's competent persons bulletin says a competent person may be a licensed electrician or someone who completed a structured course and was deemed competent with a pass-fail portable appliance tester, and that testing which needs equipment dismantled should be done by a licensed electrician. That bulletin is dated before the 2024 change, so confirm the current wording with NT WorkSafe.
What stays the same everywhere
- Competent person. Every jurisdiction expects one. A recognised course on pass-fail portable appliance testing is the usual route for non-electricians.
- Hostile environments are the trigger. Kitchens, workshops, outdoor and wet areas, and construction sites are where testing is clearly required. Offices are treated as lower risk in the NT and elsewhere.
- Fail means out of service. Tag it out, and don't return it to use until it's repaired and retested.
- Records show four things. SafeWork SA and NT WorkSafe both list who tested, when, the result, and when the next test is due. The Tasmanian and ACT pages we read don't itemise them, but keeping the same four details there is a sensible default. Our guide to test and tag records covers what to keep, and what goes on a test tag covers the tag itself.
- Construction sites follow AS/NZS 3012. Shorter intervals and daily RCD checks apply.
A checklist for clients in these four jurisdictions
- Confirm the jurisdiction's current rules on the regulator's page and note the date you checked.
- Classify each area as higher or lower risk and write down why.
- Set intervals from the regulator's table if there is one (SA), the code and standards otherwise, and any insurer or contract requirements.
- Check your own competence evidence, such as your statement of attainment or electrical licence, and keep it with the job.
- Test RCDs separately, fixed and portable, to the client's jurisdiction.
- Record all four details for every item and tag out failures.
- Leave the client a register so they can see what's due next.
Keeping several jurisdictions straight
If you work across a state border, such as Canberra and regional NSW or Darwin and the Territory's remote sites, one client's schedule can differ from the next. Koalaris keeps a register for each client and site, records tests in a field app that works offline, prints test tags and produces certificates, and clients can check their own records in a free portal. Every business can start on the Free plan with no card and no end date, and the Solo plan adds invoicing for $29 a month. See how it works on the Koalaris test and tag app page.
Frequently asked questions
Is test and tag mandatory in South Australia, Tasmania, the ACT and the NT?
For plug-in equipment used where it's likely to be damaged, yes in each: SafeWork SA and WorkSafe ACT describe it as a requirement, and NT WorkSafe sets it out in the Electrical Safety Regulations 2024. WorkSafe Tasmania says periodic testing and tagging must be done. Low risk areas like offices are treated more loosely, so check the regulator page.
Do I need an electrician's licence to test and tag?
Not in Tasmania, where it isn't a licensed occupation, and not in SA or the NT if you are a competent person with suitable training. WorkSafe ACT says inspections are done by a licensed electrician or a person certified as competent. Repairs and anything that needs equipment dismantled can be electrical work needing a licence.
How often do I test in South Australia?
SafeWork SA publishes its own interval table. For example, it lists 6 months for factories and workshops and 12 months where equipment is flexed in normal use or in a hostile environment. Check the full table, including RCD and construction intervals, on the SafeWork SA page.
Which regulations apply to test and tag in the Northern Territory now?
Since 1 July 2024, regulations 67 to 71 of the Electrical Safety Regulations 2024, according to NT WorkSafe. Older guides citing the Work Health and Safety (National Uniform Legislation) Regulations 2011 may be out of date.
Does a new appliance need testing before first use?
SafeWork SA and NT WorkSafe both say brand-new equipment doesn't need testing first but must be inspected for damage. Second-hand equipment and anything repaired should be tested before use, according to NT WorkSafe.
Keep reading
GuidesTest and tag for events and markets: a guide for operators
Test and tag for events and markets: what organisers and councils ask stallholders for, AS/NZS 3002, leads and RCDs, and how operators run event-day testing.
How-toTest and tag register template (free CSV) and how to fill it in
Download a free test and tag register template in CSV. What each column means, the extra columns worth adding, and how to stop Excel breaking your tag numbers.
GuidesChanging test and tag software without losing your history
Changing test and tag software? When to switch in the retest cycle, how to keep your tags, asset numbers and old certificates, and what to tell your clients.
See your register the way Lyra sees it.
Start free, for as long as you like. No card needed.