Test and tag visual inspection: a checklist for every item
A practical test and tag visual inspection checklist: plugs, cords, anchorage, casings, controls, guards and heat damage, plus how to record visual fails.

A test and tag visual inspection checklist covers the parts of an item you can check by eye and hand before you plug it into a tester: the plug and its pins, the cord along its full length, where the cord is anchored at each end, the casing, the controls, guards and covers, the vents, and any sign of heat, chemical or water damage. It also includes one check people forget: that the plug's current rating matches the equipment. The inspection comes first, and an item that fails it is tagged out without going any further.
This guide is for test and tag operators and new technicians. It sets out what the regulators actually list, a checklist you can work through on site, the faults that catch people out, and how to record a visual fail so the client knows what to do with it.
General information only, not legal advice. The checks below come from regulator guidance. Check the current edition of AS/NZS 3760, your state or territory regulator and any site rules before you rely on them.
Why the visual inspection matters
Testing finds faults you can't see, like a breakdown in insulation or a high-resistance earth. The inspection finds the ones you can: a cut sheath, a cracked plug or a cord pulled out of its clamp. Both are part of the job.
The model code of practice, Managing electrical risks in the workplace, puts it simply. Regular visual inspection can identify obvious damage, wear or other conditions that might make equipment unsafe, many electrical defects are detectable by visual inspection, and regular testing detects the faults and deterioration that inspection can't (SafeWork NSW code of practice). WorkSafe Victoria says the same in its own guidance: testing is needed for faults that can't be found by visual inspection (WorkSafe Victoria).
There's a practical reason too. An item with a cut cord or a broken plug isn't safe to energise, so there's no point testing it. Do the inspection first and you don't waste tests on items that have already failed.
What the regulators list
The code of practice lists what inspection and testing may involve, in part. The visual and hands-on checks are:
- looking for obvious damage, defects or modifications to the equipment, including accessories, connectors, plugs or cord extension sockets
- looking for discolouration that may indicate exposure to excessive heat, chemicals or moisture
- checking that flexible cords are effectively anchored to equipment, plugs, connectors and cord extension sockets
- looking for damage to flexible cords
- checking that operating controls are in good working order: secure, aligned and appropriately identified
- checking that covers and guards are secured and working the way the manufacturer or supplier intended
- checking that ventilation inlets and exhausts are unobstructed
- checking that the current rating of the plug matches the current rating of the equipment
The same list also includes checking protective earth and insulation resistance, which are the electrical tests that follow.
WorkSafe Victoria's list of signs of damage on leads and equipment adds detail you can use on the day: cuts, fraying and heavy scuffing; a damaged plug, bent pins or taped leads; visible internal or coloured wires; and burn marks or staining on the plug.
One note on editions. The code was written when AS/NZS 3760:2010 was current, and it refers to that edition. The current edition is AS/NZS 3760:2022 (Standards Australia), so work from the current standard for the detail.
The visual inspection checklist
Work through each item in the same order every time. It's faster, and you're less likely to skip a step at the end of a long day.
1. Plug
- Casing whole, with no cracks, chips or missing pieces
- Pins straight, firm and not loose in the body
- No burn marks, melting, staining or discolouration around the pins
- No tape holding it together
- A current rating that matches the equipment (for example, a 15 A appliance shouldn't be on a 10 A plug)
- On a rewireable plug, the cover screws in place and the cord clamp gripping the outer sheath, not the inner cores
2. Cord
Run the cord through your hand from the plug to the appliance. Damage often sits where you can't see it from a distance.
- No cuts, splits or heavy scuffing in the outer sheath
- No inner cores or coloured insulation showing anywhere
- No crush damage, kinks or flattened sections
- No tape or joins along its length
- No signs of heat, such as hardened, softened or discoloured sections
3. Cord anchorage at both ends
- The cord held firmly where it enters the appliance and the plug, with no movement when you give it a gentle tug
- The outer sheath running all the way into the grommet or clamp, with no inner cores exposed at the entry point
4. Casing and body
- No cracks, holes, missing panels or loose screws
- No signs of the item having been opened and modified
- No scorching, melting or discolouration that suggests overheating
- No staining or corrosion that suggests chemicals or water have got in
5. Controls, guards and vents
- Switches and dials secure, aligned and clearly marked
- Guards and covers fitted, secure and working as the manufacturer intended
- Vents and fan inlets clear of dust, lint or blockages
6. Extension leads, powerboards and outlet devices
These take the most knocks. Check every socket for cracks and heat marks, the cord at both ends, and that the item isn't daisy-chained or modified. Treat a powerboard with a cracked case or a melted outlet as a fail.
7. Rating plate
While you have the item in your hands, read the rating plate for the make, model, serial number and whether it's Class I or Class II. That decides which tests come next. Our guide to the appliance rating plate explains each marking.
Faults that catch people out
- Tape over damage. Electrical tape on a cord or plug is almost always covering something. Fail it rather than peel it back on site.
- Damage at the cord entry. The first few centimetres of cord, where it flexes every time someone moves the item, is where the sheath splits most often.
- Heat damage on plugs. A brown or melted mark near one pin can mean a poor connection inside the plug. It isn't always obvious until you look closely.
- Wrong plug for the job. A replacement plug fitted by someone who wasn't licensed to do it, or a plug with a lower current rating than the appliance, is a modification the code tells you to look for.
- Equipment that has been opened. Missing screws, scratched screw heads or mismatched parts can mean someone has been inside it.
What to do when an item fails the visual inspection
Don't test it. Tag it out of service with the reason, make sure it's unplugged and withdrawn from use, tell the client and record it.
In Queensland, the regulator's guidance says equipment that fails should be immediately taken out of use and a durable tag must be attached warning people not to use it (WorkSafe Queensland). The same page notes that it's an offence to repair electrical equipment without the appropriate electrical work licence, so a test and tag qualification on its own doesn't let you swap the plug.
Write the actual fault on the tag and in the record: "outer sheath cut 20 cm from plug, inner cores visible" is useful to the client and the repairer, while "failed visual" isn't. Our guide to failed test and tag items covers the repair, replace or dispose decision and when a repaired item needs retesting.
Pre-use checks are the client's job
Your inspection happens once per test interval. Damage happens in between. WorkSafe Victoria says a visual inspection of leads and equipment should always be done before use, and points out that a test tag doesn't necessarily mean the equipment is in good condition, because it may have been damaged since it was tested.
That's worth passing on to clients, especially on sites where equipment works hard. You can't replace their own checks, but you can show staff what a failed cord looks like and leave a short list of the signs above. How often the formal inspection and test is due depends on the environment, which our test and tag frequency guide covers.
Recording the inspection in Koalaris
In the Koalaris field app, the inspection and readings are recorded together for each item, and it works offline when a site has no signal. Every notes box has a mic for dictation, so you can say the fault instead of typing it with a plug in your other hand. With "Say it", you say the inspection and the readings and Lyra AI fills in the sheet and suggests a result, but nothing is saved until you tap Pass or Fail yourself. Every business starts on the Free plan, with no card and no end date. See how it works on site on the Koalaris test and tag app page.
Frequently asked questions
What is checked in a test and tag visual inspection?
The plug and pins, the cord along its length, the cord anchorage at both ends, the casing, the controls, guards and covers, and the vents. You also look for discolouration from heat, chemicals or moisture, signs the item has been modified, and whether the plug's current rating matches the equipment.
Does the visual inspection come before or after the electrical tests?
Before. An item with visible damage isn't safe to energise, so it's tagged out without being tested. The electrical tests then find the faults the inspection can't see.
Can an item pass the electrical tests but fail the visual inspection?
Yes. A cord with a cut sheath can still give good earth and insulation readings on the day. The damage still makes it unsafe, so it fails.
Is taped electrical cord a fail?
Treat it as one. WorkSafe Victoria lists taped leads among the signs of damage, and tape on a cord or plug usually hides a cut or a join. Tag it out and let the client decide whether to repair or replace it.
Who can do the visual inspection?
As part of test and tag, the inspection is done by the competent person doing the testing. Workers should still check leads and equipment for obvious damage before each use, as WorkSafe Victoria recommends, but that pre-use check doesn't replace the scheduled inspection and test.
Keep reading
GuidesTest and tag for events and markets: a guide for operators
Test and tag for events and markets: what organisers and councils ask stallholders for, AS/NZS 3002, leads and RCDs, and how operators run event-day testing.
How-toTest and tag register template (free CSV) and how to fill it in
Download a free test and tag register template in CSV. What each column means, the extra columns worth adding, and how to stop Excel breaking your tag numbers.
GuidesChanging test and tag software without losing your history
Changing test and tag software? When to switch in the retest cycle, how to keep your tags, asset numbers and old certificates, and what to tell your clients.
See your register the way Lyra sees it.
Start free, for as long as you like. No card needed.