Test and tag compliance reports your clients will actually read
How to build a test and tag compliance report clients read: what's current, overdue and failed, site by site, and how it differs from a certificate.

A test and tag compliance report tells a client where their whole register stands today: how many items are current, which are overdue or due soon, which failed and what happened to them, and which items on the register weren't found. It answers one question, "are we up to date?", in a minute of reading. A certificate records one visit. A compliance report shows the state of every item the client owns, across every site, at a point in time.
This guide is for test and tag operators. It covers what clients look for in a compliance report, a structure that puts the answers first, how to count the numbers so they hold up, and how to deliver it so clients don't ask you for it again.
General information only, not legal advice. Check the current WHS or electrical safety regulation where you work, AS/NZS 3760 and any client or contract requirements.
Compliance report vs certificate
Most operators already send a certificate after each visit. Our guide to what to put on a test and tag certificate covers that document in detail. A compliance report sits on top of it.
| Certificate | Compliance report | |
|---|---|---|
| Covers | One visit, one site | The whole register, one or many sites |
| Answers | What was tested on this day? | Where do we stand right now? |
| Includes | Items tested, results, next due dates | Current, overdue, due soon, failed, not found |
| Useful for | Filing the visit, the item record | Managers, audits, insurers, budgeting the next visit |
| Goes out of date | Never, it records a day | Quickly, as due dates pass |
The law asks for neither by name. In states using the model WHS Regulations, the record of testing must show who tested the item, the date, the outcome and the next due date, and a tag, logbook, register or computerised database can hold it (SafeWork SA). Our guide to test and tag records the law requires covers the state differences. A compliance report is a service you add: it turns those records into something a manager can act on.
What clients actually want to know
The person reading the report is rarely the person who uses the equipment. It's usually an office manager, a centre director, a site supervisor or a facilities manager, and they want quick answers to a few questions:
- Are we up to date? One number or one line, not a 400-row table.
- What's overdue, and why? Items past their due date, and whether they've been missed, moved or removed.
- What's coming up? Items due in the next 30, 60 or 90 days, so they can book the next visit and budget for it.
- What failed, and is it dealt with? Each failure with what you did on the day and what the client still needs to do.
- Is anything missing? Items on the register you couldn't find or reach.
- How does each site compare? For clients with several sites, which ones need attention.
If the report answers those in the first page, it gets read. Everything else can sit behind it.
A structure that puts the answers first
Page one: the summary
- The headline. "412 of 430 items are within their retest date. 11 are overdue and 7 failed at the last visit." Write it as a sentence, with the date the report was produced.
- Overdue items. A short list: asset ID, description, location, due date, and why, if you know ("not presented on the day", "in for repair").
- Due soon. A count for the next 30, 60 and 90 days, with the earliest dates.
- Open actions. Failed items still waiting on repair, replacement or disposal, and items not found. Give each one an owner: the client, you, or their electrician.
Page two: by site
For clients with more than one site, a row per site: items on the register, current, overdue, due in 90 days and open failures. A childcare group or a builder with several projects can see in one glance which site to chase.
The detail
Then the full register, grouped by site and location, with each item's last test date, result and next due date. Most readers never get this far. Auditors and insurers do, so it needs to be complete.
Count the numbers so they hold up
A compliance percentage is only as good as its definitions. Decide them once and state them on the report:
- What counts as current. An item is current when today is on or before its next due date. Don't round "due tomorrow" into "fine for the year".
- What's in the total. Count items on the active register. Items permanently removed or disposed of come off the total, and say so: under the model WHS Regulations, their test record only has to be kept until the item is next tested, permanently removed from the workplace or disposed of (SafeWork SA).
- Failures aren't current. A failed item is out of service until it's repaired and retested, or replaced. Leaving it in the "current" count makes the headline look better and hides the item the client most needs to deal with.
- Not-found items stay in. An item you couldn't find is still on the register. Show it as overdue or "not located" until the client confirms it's gone.
- Due dates come from the risk. Each item's interval should suit the environment it's used in, not a blanket 12 months. The test and tag frequency guide sets out the usual intervals.
Produce the report from the same register you test into. Copying results into a spreadsheet to build a report is where wrong counts and missing items come from.
Wording that keeps you out of trouble
- Report status, not safety. "Within its retest date" describes the record. "Safe" or "compliant" promises something no test can: equipment can be damaged the day after you leave.
- Say what the report is based on. "Based on testing to AS/NZS 3760:2022 recorded up to 9 November 2026" tells the reader where the numbers come from and when.
- Be plain about gaps. If you weren't given access to a building or a store room, say so. A report that only covers what you could reach should say which parts it doesn't cover.
Construction and demolition sites
Construction sites follow AS/NZS 3012 and carry heavier record keeping. SafeWork SA's guidance lists what must be recorded and kept on site or made available for audit: a register of all equipment, a record of formal inspections and tests, a repair register, and a record of faulty equipment with the corrective action taken. It also says RCD test results must be kept for at least five years, apart from the daily push-button test on portable RCDs (SafeWork SA). A compliance report for a builder should show all four, by site, and the retest intervals on site are much shorter, so the "due soon" list matters even more. Check the rules where the site is, as other states set out construction requirements in their own way.
How often to send it, and how
- After every visit. Send the certificate for the visit and an updated summary of the whole register with it.
- Before the next visit is due. A short "here's what's coming up" summary a month or so before the next round is booked doubles as a rebooking prompt.
- On request, for audits. Accreditation, insurance renewals and head contractor checks often need a current report at short notice.
Email works, but a PDF goes out of date as soon as due dates pass. A client portal stays current: the client signs in and sees their register as it is today, with every certificate and report from past visits. It also ends the "can you resend last year's report?" emails.
Compliance reports in Koalaris
In Koalaris, clients get a free, read-only portal on every plan. They see a compliance overview and what's coming up, browse their own register and each item's history, and download their certificates, reports and register as a spreadsheet. They never see your prices or invoices, or any other client's data. For aged care and other facilities, the overview also shows how ready the site is for an audit and which way it's heading, month by month. Everything you record in the field app appears for them straight away. See the client portal and reporting features for more.
Certificates carry a short plain-English summary of the results. On the Pro plan, Lyra AI also writes the wording of full compliance summaries for clients, while every number in them is calculated by Koalaris, not the AI.
You can start on the Free plan with no card and no end date: unlimited items, clients and sites, certificates with your logo and the client portal included.
Frequently asked questions
Is a test and tag compliance report a legal requirement?
Not by that name. In model WHS states, the law requires a record of testing showing who tested the item, the date, the outcome and the next due date. A compliance report is a summary built from those records that makes them useful to the client.
What's the difference between a test and tag report and a certificate?
People use the terms loosely. A certificate usually records one visit: what was tested and the result for each item. A compliance report shows where the client's whole register stands right now, including items that are overdue, due soon, failed or not found.
How often should I send a compliance report?
After every visit, and again before the next round of testing is due. Clients with several sites, or clients facing an audit, may want one every quarter. A client portal removes the need to send it at all, because the client can check at any time.
Should failed items count as compliant?
No. A failed item is out of service until it's repaired and retested, or replaced. Show it as an open action with what the client needs to do.
What should I do about items I couldn't find?
Keep them on the register and list them as not located. Ask the client to confirm whether each item was removed, disposed of or is somewhere you didn't get to, and update the register when they reply.
Keep reading
GuidesTest and tag for events and markets: a guide for operators
Test and tag for events and markets: what organisers and councils ask stallholders for, AS/NZS 3002, leads and RCDs, and how operators run event-day testing.
How-toTest and tag register template (free CSV) and how to fill it in
Download a free test and tag register template in CSV. What each column means, the extra columns worth adding, and how to stop Excel breaking your tag numbers.
GuidesChanging test and tag software without losing your history
Changing test and tag software? When to switch in the retest cycle, how to keep your tags, asset numbers and old certificates, and what to tell your clients.
See your register the way Lyra sees it.
Start free, for as long as you like. No card needed.